KSM2000
OIL DIFFUSION EJECTOR PUMP

- High Throughput: 2500 liters
/ second at 10-3 Torr range.
- Efficient Heat Transfer: replaceable
immersion heaters reduce heat loss
- Oil Sight level
- Oil Temperature monitor
- Foreline Ejector stage allows
operation at higher pressures (up to 1 Torr)
- Fast Pump Down Times
- Cooling and quench coils
- Optional Boiler Insulation Jacket
The KSM-2000 is a three stage high
vacuum (10-3 to 10-4 Torr range) vapor pump
designed for heavy gas load applications such as in vacuum distillation,
evaporation, vacuum arc melting, freeze drying, impregnation and
casting of metals. The pump has no moving parts which may be corroded
by the acidic nature of the material being pumped. These pumps
may be used in place of mechanical roots type blower pumps.
The KSM-2000 is a three stage vapor
pump whose diffusion and ejector nozzles are supplied from a common
electrically heated boiler.
Two umbrella type vapor stages,
positioned in the vertical column, have nozzles through which
jets of vapor are emitted to entrain the gas entering the pump
inlet. The compressed gas is then passed on to the ejector stage
in the horizontal convergent divergent arm of the pump.
The pump achieves a peak operating
pumping speed of 2500 liters/second at 10-3 Torr and
has an ultimate pressure in the 10-4 Torr range. The
ejector stage is operated at a sufficiently high boiler pressure
to handle gas loads in the 10-1 Torr pressure range
and also provides a forepressure tolerance of greater than 1 Torr.
The pump comes equipped with water-cooling
lines with disconnect fittings and vacuum flanges which allows
for easy maintenance disassembly. On board oil temperature and
oil level indicators allow for ease of system monitoring during
operation. Quench lines in the boiler provide rapid cooling of
oil when systems operation is stopped (these connections are standard
¾" allowing for use of standard water hoses for temporary connection
when needed). The external boiler which supplies the vapor is
equipped with replaceable blade type immersion heaters.
An optional thermal jacket is available
for the boiler housing. This will reduce heat loss and power consumption
during operation. It is attached using high temperature Velcro
strips. This allows for easy removal to avoid contamination by
cleaning solvents and oil during maintenance.
| Inlet
connection |
Flange
|
|
- O.D. |
19"
|
|
- I.D. |
12"
|
|
- Thickness |
1-1/4"
|
|
- Bolt circle |
17"
|
|
- No. of holes |
12 |
|
- Hole diameter |
1"
|
|
- Gasket Groove O.D. |
13-3/4"
|
|
- Gasket Groove I.D. |
13"
|
| Outlet
connection |
Flange
|
|
- O.D. |
9"
|
|
- I.D. |
3-7/8"
|
|
- Thickness |
5/8"
|
|
- Bolt circle |
7-1/2"
|
|
- No. of holes |
8 |
|
- Hole diameter |
3/4"
|
|
- Gasket Groove O.D. |
6-1/8"
|
|
- Gasket Groove I.D. |
5-3/8"
|
| Cooling
Connections |
3/8" FPT
(Boiler is 3/4"FPT) |
| Mounting
Holes |
4-1" dia.
on 24x20" centers |
| Maximum
Width |
28-3/4
at sight glass |
| Space
for heater removal |
38"
|
| Heater
Voltage (Rated) |
240, 480,
or 550v, 3ph.(as requested by customer) |
| Heater
Wattage (Rated) |
12000w
|
| Pump Fluid
(Quantity) |
10 gal.
|
| Net weight
|
780 lbs.
|
| Shipping
weight |
930 lbs.
|
| Recommended
backing pump speed |
130 cfm
|
Plateau
speed
(liters per second) |
2500
|
Typical
air throughput In pumpdown range
(Torr-liters per second) |
40
|
| Backing
speed required for highest throughput time (cfm)
|
300
|
| Warm-up
time (minutes) |
60
|
| Cooling
water - temp. º in |
20
|
| Cooling
water - temp. º out |
45-55
|
Nominal
cooling rate
(gallons per minute) |
1.5
|
| Recommended
forepump (cfm) |
220
|
Cool-down
time to 100º C
(using quench coils) |
60
|
All data obtained with Convoil-20
pump fluid.
Pumping speed measured with Convoil 20 diffusion pump.
|
Ordering information for the components mentioned
on this page is listed below.
| ITEM
|
DESCRIPTION
|
P/N
|
| KSM-2000
|
Diffusion
ejector pump cr. stl., water-cooled 3ø, 12KW, 230V. Immersion
heater. |
500385
|
| KSM-2000
|
Jet assembly
|
500361
|
| Replacement
heaters |
for
KSM-2000, 240/480V, 12 KW, 3 Phase On 6" ASA Flange |
500375
|
| Insulation
Jacket |
Removeable
Thermal Jacket for boiler housing |
500383 |
| Over
temperature Protection |
Cooling
Coil Thermocouple Switch Kit |
274366 |
|